% RH
Feuchtefühler in Frontalansicht mit geschlossenem Gehäuse
Feuchtefühler mit geschlossenem Gehäuse und weißem Schutzrohr
Feuchtefühler mit geschlossenem Gehäuse und Schutzrohr mit Metallschutz

On-wall humidity sensor / outdoor humidity sensor HYGRASGARD® AFF-SD-U

SKU 1201-1121-0000-100 EAN 4 251325 609966 Product group: WG01B
In stock Available for delivery to in 1-3 business days

Country/region

Shipping calculated at checkout.
Regular price 205,43 €
Regular price Sale price 205,43 €

Auf die Merkliste

Add to wishlist

Añadir a la lista de favoritos

Aggiungi alla lista dei preferiti

Добавить в список желаний

Ajouter à la liste de souhaits

Product description

  • 0...100 % RH
  • Measurement accuracy: ± 2 %
  • relative humidity [% RH]
  • 0 - 10 V
  • IP 65
Quality product for the HVAC sector, accuracy 2 % RH
The calibratable outdoor humidity/temperature sensor HYGRASGARD® AFF - SD / AFTF-SD measures the relative humidity and/or temperature of the air. It converts the measured variable into a standard signal of 0-10 V or 4...20 mA, is optionally available with/without display, with terminal box housing made of impact-resistant plastic, housing cover with quick-locking screws.
The measuring transducer has four switchable temperature ranges and is used in non-aggressive, dust-free environments, in refrigeration, air conditioning, ventilation and clean room technology. The relative humidity (in % RH) is the quotient of the water vapor partial pressure and the saturation vapor pressure at the respective gas temperature. The device is designed for the exact measurement of humidity and uses a digital, long-term stable sensor as the measuring element. The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.

Technical data

Measurement relative humidity
Power supply 24 V AC (± 20 %) and
15...36 V DC
Output 0-10V
Display No
Measured quantity in addition to °C + %RH none
Measuring range 0...100 % RH
Features sinter filter, plastic
Output 0 - 10 V
Humidity sensor tolerance 2 %

Blog posts

Differenzdruck im Reinraum: Druckkaskaden und Sensorwahl

Differential pressure in cleanrooms: pressure c...

How is a pressure cascade created in a cleanroom? Planning guide for reference rooms, differential...

Differential pressure in cleanrooms: pressure c...

How is a pressure cascade created in a cleanroom? Planning guide for reference rooms, differentia...

Reinraumüberwachung: Sensorik für Druck, Temperatur und Feuchte

Cleanroom Monitoring: Sensors for Pressure, Tem...

What sensors are required for cleanroom monitoring? A guide to measurement tasks, measurement locations, data...

Cleanroom Monitoring: Sensors for Pressure, Tem...

What sensors are required for cleanroom monitoring? A guide to measurement tasks, measurement loc...

Temperatur in Rechenzentren überwachen: Sensorik richtig planen

Monitoring temperatures in data centers: Planni...

How temperature, humidity, dew point, and differential pressure interact: a measurement and monitoring concept for...

Monitoring temperatures in data centers: Planni...

How temperature, humidity, dew point, and differential pressure interact: a measurement and monit...

W-Modbus: Pairing Feldgerät-Gateway

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a...

W-Modbus: Pairing a Field Device with a Gateway

In this video setup guide, we'll show you how to connect a gateway to a field device via W-Modbus...

Wireless BACnet (W-BACnet) – Drahtlose Gebäudeautomation mit maximaler Flexibilität

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Buildings are...

Wireless BACnet (W-BACnet) – Wireless Building ...

Author: T. Graf The demands placed on modern building automation are constantly growing. Building...

BACnet – Der offene Kommunikationsstandard

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperature, humidity, and CO₂...

BACnet – The Open Communication Standard

Author: T. Graf Modern buildings are becoming increasingly intelligent. Sensors measure temperatu...

Feuchtesensoren für Tierhaltung und Agrar

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-condensation...

Humidity Sensors for Animal Husbandry and Agric...

In our previous post, we already explained the specific demands that high humidity and near-conde...

Feuchtesensoren für Schwimmbad und Wellnessbereich

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, and harsh...

Humidity Sensors for Swimming Pools and Spa Areas

In our previous article, we described the specific challenges that high humidity, condensation, a...

Hochfeuchtesensorik in Industrie & Fertigung

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh environmental...

High-Humidity Sensors in Industry & Manufacturing

In our previous post, we described the challenges that high humidity, condensation, and harsh env...

We also manufacture individually

Do you have special requirements? As a manufacturer with our own production facilities in Germany, we are always in a position to produce products outside the standard range.

Contact us

Secure payment methods

  • American Express
  • Apple Pay
  • Bancontact
  • Bizum
  • EPS
  • Google Pay
  • iDEAL Wero
  • Klarna
  • Maestro
  • Mastercard
  • MB WAY
  • MobilePay
  • PayPal
  • Przelewy24
  • Satispay
  • Union Pay
  • Visa

Do you have a question? We are at your disposal:

+49 911 519 470

Mo. - Fr. 7.00am - 5.00pm CEST