{"title":"VOC sensors","description":"\u003cp\u003eA ventilation system equipped with VOC sensors can optimize indoor air quality while minimizing energy consumption. Our AERASGARD® VOC sensors detect indoor air pollution from contaminated gases such as cigarette smoke, breathing, paints, cleaning agents, office supplies, bodily functions, etc.\u003c\/p\u003e","products":[{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-und-co2-gehalt-aerasgard-aftm-lq-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-7118-7301-500","title":"AERASGARD® AFTM-LQ-CO2-W","description":"Maintenance-free surface-mounted room climate sensor AERASGARD® AFTM - CO2 - W\/ ASGARD® AFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255341973835,"sku":"1501-7118-7301-500","price":650.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2__tyr2-K_maxi-mL_4c_e4620f9a-f728-4223-8b7d-34199d11cd5b.png?v=1769649932"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-und-co2-gehalt-aerasgard-aftm-lq-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-1501-7118-7371-500","title":"AERASGARD® AFTM-LQ-CO2-W LCD","description":"Maintenance-free surface-mounted room climate sensor AERASGARD® AFTM - CO2 - W\/ ASGARD® AFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255345217867,"sku":"1501-7118-7371-500","price":778.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-W-Display-350ppm-OC__tyr2-K_maxi-mL_4c_184cd81d-7a38-4c27-8a83-744379cb0578.png?v=1769650006"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-aftm-lq-co2-modbus-modbus-rtu-1501-7118-6001-500","title":"AERASGARD® AFTM-LQ-CO2-Modbus","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). \u003cbr\u003e\u003cbr\u003eThe following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255345414475,"sku":"1501-7118-6001-500","price":663.99,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-Modbus__tyr2-K-2xKV_maxi-mL_4c_e79938f9-82c6-4711-892b-6a274da0012e.png?v=1769649803"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-aftm-lq-co2-modbus-lcd-modbus-rtu-display-1501-7118-6071-500","title":"AERASGARD® AFTM-LQ-CO2-Modbus LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). \u003cbr\u003e\u003cbr\u003eThe following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255345545547,"sku":"1501-7118-6071-500","price":785.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/AFTM-LQ-CO2-Modbus-Display__tyr2-K-2xKV_maxi-mL_4c_22a66666-29e7-4d03-ac13-225791cdfa13.png?v=1769649782"},{"product_id":"aufputzfuehler-fuer-co2-gehalt-und-luftguete-aerasgard-alq-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-7111-7301-500","title":"AERASGARD® ALQ-CO2-W","description":"Maintenance-free surface-mounted sensor AERASGARD® ALQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and day room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of buildings, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255345905995,"sku":"1501-7111-7301-500","price":516.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-W__tyr2_maxi-mL_4c.png?v=1769649653"},{"product_id":"aufputzfuehler-fuer-co2-gehalt-und-luftguete-aerasgard-alq-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-1501-7111-7371-500","title":"AERASGARD® ALQ-CO2-W LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® ALQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and day room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of buildings, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255346200907,"sku":"1501-7111-7371-500","price":583.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-W-350ppm-OC__tyr2_maxi-mL_4c.png?v=1769649678"},{"product_id":"aufputz-luftqualitaets-voc-und-co2-fuehler-aerasgard-alq-co2-modbus-modbus-rtu-1501-7111-6001-500","title":"AERASGARD® ALQ-CO2-Modbus","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or ACO2\/ ALQ - CO2\/ AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255346594123,"sku":"1501-7111-6001-500","price":558.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-Modbus__tyr2-2xKV_maxi-mL_4c_4ff11e16-810c-403f-8e5d-bf7762eb3449.png?v=1769648677"},{"product_id":"aufputz-luftqualitaets-voc-und-co2-fuehler-aerasgard-alq-co2-modbus-lcd-modbus-rtu-display-1501-7111-6071-500","title":"AERASGARD® ALQ-CO2-Modbus LCD","description":"Maintenance-free surface-mounted sensor AERASGARD® AFTM - LQ- CO2 - Modbus (max. expansion stage) or ACO2\/ ALQ - CO2\/ AFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), temperature (-35...+80 °C) and relative humidity (0...100 % RH). International unit system SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. \u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the contamination of the room air by polluted gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255346921803,"sku":"1501-7111-6071-500","price":653.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/ALQ-CO2-Modbus-Display__tyr2-2xKV_maxi-mL_4c_68e2053a-7192-4613-a1ae-12d049ce41fa.png?v=1769648662"},{"product_id":"kanalfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-kftm-lq-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-8118-7301-500","title":"AERASGARD® KFTM-LQ-CO2-W","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KTM - CO2 - SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-release screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. .","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255364092235,"sku":"1501-8118-7301-500","price":516.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KFTM-LQ-CO2__tyr2-PA-K_maxi-mL_4c_730b817e-84d3-4378-a445-4d68fd39cf05.png?v=1769683631"},{"product_id":"kanalfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-kftm-lq-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-1501-8118-7371-500","title":"AERASGARD® KFTM-LQ-CO2-W LCD","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KTM - CO2 - SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-release screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. .","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255366156619,"sku":"1501-8118-7371-500","price":581.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KFTM-LQ-CO2-W-350ppm-OC__tyr2-PA6-K_maxi-mL_4c_2523efb6-52c8-46ef-bef3-2f3fd4c21270.png?v=1769683669"},{"product_id":"kanalfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-kftm-lq-co2-modbus-modbus-rtu-1501-8118-6001-500","title":"AERASGARD® KFTM-LQ-CO2-Modbus","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KTM - CO2 - SD\/ KFTM - CO2 - W\/ KFTM - CO2 - Wwith active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-release screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-locking screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. .","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255367303499,"sku":"1501-8118-6001-500","price":555.64,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KFTM-LQ-CO2-Modbus__tyr2-PA-K-2xKV_maxi-mL_4c_efd61363-ccb6-4517-96d3-70f35eb051c6.png?v=1769683881"},{"product_id":"kanalfuehler-fuer-feuchte-temperatur-und-co2-aerasgard-kftm-lq-co2-modbus-lcd-modbus-rtu-display-1501-8118-6071-500","title":"AERASGARD® KFTM-LQ-CO2-Modbus LCD","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KTM - CO2 - SD\/ KFTM - CO2 - W\/ KFTM - CO2 - Wwith active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-release screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. .","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255367598411,"sku":"1501-8118-6071-500","price":653.02,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KFTM-LQ-CO2-Modbus-Display__tyr2-PA-K-2xKV_maxi-mL_4c_2894ca70-c942-4d22-9712-41f9a5fb793f.png?v=1769683842"},{"product_id":"kanal-luftqualitaetsfuehler-regler-voc-aerasgard-klq-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-3150-7301-500","title":"AERASGARD® KLQ-W","description":"Patented quality product (patent no. DE 10 2014 010 719.1)\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KLQ-SD with active output, automatic calibration, in a compact plastic housing with snap-on lid, for determining the air quality or air quality (0...100 % VOC).\u003cbr\u003eThe measuring transducer converts the measured variable into a standard signal of 0-10 V.\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KLQ-W with active\/switching output, automatic calibration, in a compact plastic housing with quick-release screws, for determining air quality or air quality (0...100 % VOC). The measuring transducer converts the measured variable into a standard signal of 0-10 V or4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. The air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This\u003cbr\u003edetermines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc. With regard to the expected air contamination, a low, medium or high VOC sensitivity can be set. Alternatively, the room air can also be assessed in IAQ classifications (Indoor Air Quality from excellent to unhealthy) in accordance with the guidelines of the Federal Environment Agency. .","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255370580299,"sku":"1501-3150-7301-500","price":244.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KLQ__tyr1-PA6-oF__maxi-mL_4c_4bccc2fc-abe0-4787-97db-f1b5f5525bda.png?v=1769680665"},{"product_id":"kanal-luftqualitaetsfuehler-regler-voc-aerasgard-klq-sd-u-0-10v-1501-3170-1001-500","title":"AERASGARD® KLQ-SD-U","description":"Patented quality product (patent no. DE 10 2014 010 719.1)\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KLQ-SD with active output, automatic calibration, in a compact plastic housing with snap-on lid, for determining the air quality or air quality (0...100 % VOC).\u003cbr\u003eThe measuring transducer converts the measured variable into a standard signal of 0-10 V.\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KLQ-W with active\/switching output, automatic calibration, in a compact plastic housing with quick-release screws, for determining air quality or air quality (0...100 % VOC). The measuring transducer converts the measured variable into a standard signal of 0-10 V or4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. The air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This\u003cbr\u003edetermines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc. With regard to the expected air contamination, a low, medium or high VOC sensitivity can be set. Alternatively, the room air can also be assessed in IAQ classifications (Indoor Air Quality from excellent to unhealthy) in accordance with the guidelines of the Federal Environment Agency. .","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255370940747,"sku":"1501-3170-1001-500","price":234.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KLQ__tyr1-PA6-oF__maxi-mL_4c_05f73148-d7b9-418f-95d1-afc51e6fcbd4.png?v=1769680638"},{"product_id":"kanal-luftqualitaets-voc-und-co2-fuehler-aerasgard-klq-co2-modbus-modbus-rtu-1501-8111-6001-500","title":"AERASGARD® KLQ-CO2-Modbus","description":"\u003cp\u003ePatented quality product (patent no. DE 10 2014 010 719.1)Maintenance-free duct sensor AERASGARD® KFTM - LQ- CO2 - Modbus (max. expansion stage) or KCO2\/ KLQ - CO2\/ KFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), incl. mounting flange, optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), air quality (0...100 % VOC), incl. display. Mounting flange, optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), the air quality or air quality (0...100 % VOC), the temperature (-35...+80 °C) and the relative humidity (0...100 % RH). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus:  Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.Innovative Modbus sensor with galvanically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.\u003c\/p\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255371792715,"sku":"1501-8111-6001-500","price":467.58,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KCO2-KLQ-CO2-Modbus__tyr2-PA6-oF-2xKV_maxi-mL_4c_4e2f873b-a40e-426a-82d4-da36af00210b.png?v=1769680545"},{"product_id":"kanal-luftqualitaets-voc-und-co2-fuehler-aerasgard-klq-co2-modbus-lcd-modbus-rtu-display-1501-8111-6071-500","title":"AERASGARD® KLQ-CO2-Modbus LCD","description":"\u003cp\u003ePatented quality product (patent no. DE 10 2014 010 719.1)Maintenance-free duct sensor AERASGARD® KFTM - LQ- CO2 - Modbus (max. expansion stage) or KCO2\/ KLQ - CO2\/ KFTM - CO2 - Modbus with Modbus connection, automatic calibration, in an impact-resistant plastic housing with quick-locking screws, plastic sintered filter (replaceable), incl. mounting flange, optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), air quality or air quality (0...100 % VOC), air quality (0...100 % VOC), incl. display. Mounting flange, optionally with\/without display, for determining the CO2 content of the air (0...5000 ppm), the air quality or air quality (0...100 % VOC), the temperature (-35...+80 °C) and the relative humidity (0...100 % RH). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus:  Temperature, relative humidity, air quality (VOC), carbon dioxide (CO2) and atmospheric air pressure. The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring.  Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc.  A low, medium or high VOC sensitivity can be set for the expected air contamination.Innovative Modbus sensor with galvanically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and large three-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range).  The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.\u003c\/p\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255372480843,"sku":"1501-8111-6071-500","price":546.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KCO2-KLQ-CO2-Modbus-Display__tyr2-PA6-oF-2xKV_maxi-mL_4c_a66eb0de-d632-476c-a6b1-1992f982137c.png?v=1769680525"},{"product_id":"kanal-luftqualitaets-voc-und-co2-fuehler-aerasgard-klq-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-8111-7301-500","title":"AERASGARD® KLQ-CO2-W","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KLQ-SD with active output, automatic calibration (fixed setting), in a compact plastic housing with snap-on lid, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KLQ-W with active\/switching output, automatic calibration (can be switched off), in a compact plastic housing with quick-locking screws, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e The air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255373037899,"sku":"1501-8111-7301-500","price":430.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KLQ-CO2-W__tyr2-PA6-oF__maxi-mL_4c.png?v=1769680564"},{"product_id":"kanal-luftqualitaets-voc-und-co2-fuehler-aerasgard-klq-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-1501-8111-7371-500","title":"AERASGARD® KLQ-CO2-W LCD","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KLQ-SD with active output, automatic calibration (fixed setting), in a compact plastic housing with snap-on lid, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KLQ-W with active\/switching output, automatic calibration (can be switched off), in a compact plastic housing with quick-locking screws, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e The air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255373627723,"sku":"1501-8111-7371-500","price":495.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KLQ-CO2-W-520ppm-OV__tyr2-PA6-oF_maxi-mL_4c.png?v=1769680595"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-rftm-lq-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-61b8-7301-500","title":"AERASGARD® RFTM-LQ-CO2-W","description":"Maintenance-free room climate sensor AERASGARD® RFTM - CO2 - W\/ RFTM - LQ - CO2 - W\/ RTM - CO2 - SD with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (0...+50°C) and the relative humidity (0...100 % RH). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255379427659,"sku":"1501-61B8-7301-500","price":454.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_7b0e10c8-06fe-4906-98c9-51c8de7e60e7.png?v=1762857754"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-rftm-lq-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-display-1501-61b8-7321-500","title":"AERASGARD® RFTM-LQ-CO2-W LCD","description":"Maintenance-free room climate sensor AERASGARD® RFTM - CO2 - W\/ RFTM - LQ - CO2 - W\/ RTM - CO2 - SD with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (0...+50°C) and the relative humidity (0...100 % RH). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255380083019,"sku":"1501-61B8-7321-500","price":509.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Display-ppm__baldur2_maxi-mL_4c_b328ddd9-600c-4262-9cce-7006d2b8172f.png?v=1762857783"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftqualitaet-voc-feinstaub-pm-und-co2-aerasgard-rftm-ps-lq-co2-modbus-modbus-rtu-1501-2119-6001-500","title":"AERASGARD® RFTM-PS-LQ-CO2 Modbus","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255381524811,"sku":"1501-2119-6001-500","price":621.32,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_6e300a67-1003-4ba9-93b1-50a9f588c950.png?v=1762857894"},{"product_id":"raumfuehler-fuer-feuchte-temperatur-luftqualitaet-voc-feinstaub-pm-und-co2-aerasgard-rftm-ps-lq-co2-modbus-lcd-modbus-rtu-display-display-1501-2119-6021-500","title":"AERASGARD® RFTM-PS-LQ-CO2 Modbus LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255381983563,"sku":"1501-2119-6021-500","price":676.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-PS-CO2-Modbus-Display-index6__baldur2_maxi-mL_4c.png?v=1762857930"},{"product_id":"raum-luftqualitaetsfuehler-voc-aerasgard-rlq-sd-u-0-10v-ohne-anzeige-1501-61c0-1001-500","title":"AERASGARD® RLQ-SD-U","description":"Maintenance-free room climate sensor AERASGARD® RLQ - SD with active output, automatic calibration (fixed setting), in an attractive plastic housing with snap-on lid, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free room climate sensor AERASGARD® RLQ - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on cover, optionally with traffic light display (five colored LEDs), for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eThe air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. \u003cbr\u003e\u003cbr\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255390273867,"sku":"1501-61C0-1001-500","price":190.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RLQ__baldur1_maxi-mL_4c_da26bb25-3f20-45b0-991f-1a392f16dfea.png?v=1769689593"},{"product_id":"raum-luftqualitaetsfuehler-voc-aerasgard-rlq-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-61c0-7301-500","title":"AERASGARD® RLQ-W","description":"Maintenance-free room climate sensor AERASGARD® RLQ - SD with active output, automatic calibration (fixed setting), in an attractive plastic housing with snap-on lid, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free room climate sensor AERASGARD® RLQ - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on cover, optionally with traffic light display (five colored LEDs), for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eThe air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. \u003cbr\u003e\u003cbr\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255391551819,"sku":"1501-61C0-7301-500","price":199.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RLQ__baldur1_maxi-mL_4c_c63cc5a4-fa99-49be-ba00-5c42feb69a21.png?v=1769689617"},{"product_id":"raum-luftqualitaetsfuehler-voc-aerasgard-rlq-w-a-0-10v-4-20ma-1-wechsler-24-v-led-led-anzeigen-wechsler-led-ampel-1501-61c0-7331-500","title":"AERASGARD® RLQ-W-A","description":"Maintenance-free room climate sensor AERASGARD® RLQ - SD with active output, automatic calibration (fixed setting), in an attractive plastic housing with snap-on lid, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free room climate sensor AERASGARD® RLQ - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on cover, optionally with traffic light display (five colored LEDs), for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eThe air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. \u003cbr\u003e\u003cbr\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255392862539,"sku":"1501-61C0-7331-500","price":227.39,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RLQ-A__baldur1_maxi-mL_4c_481fc3d8-d5db-4b8b-a43a-87260c9bac97.png?v=1769689640"},{"product_id":"raum-luftguetefuehler-raum-co2-und-luftqualitaetsfuehler-aerasgard-rlq-co2-w-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-61b1-7301-500","title":"AERASGARD® RLQ-CO2-W","description":"Maintenance-free room climate sensor AERASGARD® RLQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (0...+50°C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255395582283,"sku":"1501-61B1-7301-500","price":414.2,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RLQ__baldur1_maxi-mL_4c_10ff43ff-6bc0-496f-ab3b-a85456ecb5d8.png?v=1769689508"},{"product_id":"raum-luftguetefuehler-raum-co2-und-luftqualitaetsfuehler-aerasgard-rlq-co2-w-lcd-0-10v-4-20ma-1-wechsler-24-v-display-wechsler-1501-61b1-7321-500","title":"AERASGARD® RLQ-CO2-W LCD","description":"Maintenance-free room climate sensor AERASGARD® RLQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on lid, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (0...+50°C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. CO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. Air quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255398400331,"sku":"1501-61B1-7321-500","price":469.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Display-ppm__baldur2_maxi-mL_4c_d51f850a-e134-4458-95c8-c151f14c8045.png?v=1769689569"},{"product_id":"raum-luftguetefuehler-raum-co2-und-luftqualitaetsfuehler-aerasgard-rlq-co2-modbus-modbus-rtu-1501-61b1-6001-500","title":"AERASGARD® RLQ-CO2-Modbus","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.\u003cp\u003e\u003c\/p\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255398695243,"sku":"1501-61B1-6001-500","price":440.89,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_a51309d4-5c5e-46fd-a646-c9a6178874dd.png?v=1769689446"},{"product_id":"raum-luftguetefuehler-raum-co2-und-luftqualitaetsfuehler-aerasgard-rlq-co2-modbus-lcd-modbus-rtu-display-1501-61b1-6021-500","title":"AERASGARD® RLQ-CO2-Modbus LCD","description":"Multifunctional room climate sensor AERASGARD® RFTM-LQ-PS-CO2-Modbus (maximum expansion stage) with Modbus connection, in an attractive plastic housing with snap-on cover, lower part with 4-hole mounting, optionally with\/without display, type variant RFTM-CO2-Modbus optionally with\/without setpoint potentiometer. The room sensor is used to measure humidity (0...100 % RH), temperature (0...+50°C), air quality (VOC) (0...100 % ), particulate matter (PM) (0...1000 µg\/m3) and CO2 content (0...5000 ppm) and as a room control unit (% setpoint). International system of units SI (default) can be switched to Imperial (via Modbus). The following parameters can be called up via Modbus: Temperature, relative humidity, air quality (VOC), particulate matter (PM) and carbon dioxide (CO2). The entire indoor climate can be effectively monitored and controlled with just one device. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. It is used in offices, hotels, conference rooms, apartments, stores, etc. One sensor per 30 m² of room area is recommended. A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. The air quality is determined on the basis of a (VOC) mixed gas sensor. The CO2 content of the air is determined using an optical NDIR sensor (non-dispersive infrared technology). An optical fine dust sensor precisely detects particles (PM) in the size category 0.3 to 10 micrometres.\u003cbr\u003e\u003cbr\u003eInnovative Modbus sensor with electrically isolated RS485 Modbus interface, switchable bus terminating resistor, DIP switch for setting the bus parameters and bus address in the de-energized state, internal LEDs for telegram status display, two separate push-in terminals and two-line display (illuminated, individually programmable in the 7-segment range and dot-matrix range). The sensor is calibrated at the factory; fine adjustment by a specialist is possible depending on the environment.\u003cp\u003e\u003c\/p\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255399088459,"sku":"1501-61B1-6021-500","price":495.87,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-LQ-CO2-Modbus-Display__baldur2_maxi-mL_4c_76dcc3b8-931a-4436-9eb0-b5be4cad4a41.png?v=1769689426"},{"product_id":"raum-luftqualitaetsfuehler-voc-bzw-messumformer-aerasgard-rlq-w-va-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-61c0-7301-505","title":"AERASGARD® RLQ-W VA","description":"Maintenance-free room climate sensor AERASGARD® RLQ - SD with active output, automatic calibration (fixed setting), in an attractive plastic housing with snap-on lid, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free room climate sensor AERASGARD® RLQ - W with active\/switching output, automatic calibration (can be switched off), in an attractive plastic housing with snap-on cover, optionally with traffic light display (five colored LEDs), for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003eThe air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255399416139,"sku":"1501-61C0-7301-505","price":318.72,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/VA2-Edelstahl__maxi-mL_4c_dde752a3-2ced-4709-9617-f3f64003a8ce.png?v=1769689686"},{"product_id":"funkbussystem-kymasgard-rftm-fse-1801-4280-0000-000","title":"KYMASGARD® RFTM-FSE","description":"The room radio sensors of the KYMASGARD® 9000 radio bus system are battery-free and maintenance-free radio transmitters. Energy is generated by converting the light inside the room into electrical energy using a solar generator. If there is insufficient ambient light for energy generation, the sensors can optionally be operated with two AAA batteries (not included). They are used to record the room climate and to set setpoint values and transmit them by radio to radio actuators and radio receivers\/gateways. The following device configurations are available: \u003cbr\u003e\u003cbr\u003eThe KYMASGARD® RFTM-FSE room sensor is used to record the room temperature and room humidity. \u003cbr\u003e\u003cbr\u003eThe KYMASGARD® RFTM-FSE-ST room operating unit is used to record the room temperature and room humidity and to display and set the setpoint temperature. The setpoint is set directly on site using touch buttons. \u003cbr\u003e\u003cbr\u003eThe KYMASGARD® RFTM-LQ-FSE room sensor is used to record the room temperature and humidity as well as the air quality (VOC, volatile organic compounds). \u003cbr\u003e\u003cbr\u003eThe KYMASGARD® RFTM-BW-FSE room sensor is used to detect the room temperature and humidity as well as the movement of people (presence). \u003cbr\u003e\u003cbr\u003eThe WH-3100 wall bracket and the SH-3110 stand are available as optional accessories for using the wireless sensors as desktop devices.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255428809035,"sku":"1801-4280-0000-000","price":301.25,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-xx-FSE__solar_mini-mL_4c.png?v=1769675469"},{"product_id":"funkbussystem-kymasgard-rftm-lq-fse-1801-4280-3000-000","title":"KYMASGARD® RFTM-LQ-FSE","description":"The room radio sensors of the KYMASGARD® 9000 radio bus system are battery-free and maintenance-free radio transmitters. Energy is generated by converting the light inside the room into electrical energy using a solar generator. If there is insufficient ambient light for energy generation, the sensors can optionally be operated with two AAA batteries (not included). They are used to record the room climate and to set setpoint values and transmit them by radio to radio actuators and radio receivers\/gateways. The following device configurations are available: \u003cbr\u003e\u003cbr\u003eThe KYMASGARD® RFTM-FSE room sensor is used to record the room temperature and room humidity. \u003cbr\u003e\u003cbr\u003eThe KYMASGARD® RFTM-FSE-ST room operating unit is used to record the room temperature and room humidity and to display and set the setpoint temperature. The setpoint is set directly on site using touch buttons. \u003cbr\u003e\u003cbr\u003eThe KYMASGARD® RFTM-LQ-FSE room sensor is used to record the room temperature and humidity as well as the air quality (VOC, volatile organic compounds). \u003cbr\u003e\u003cbr\u003eThe KYMASGARD® RFTM-BW-FSE room sensor is used to detect the room temperature and humidity as well as the movement of people (presence). \u003cbr\u003e\u003cbr\u003eThe WH-3100 wall bracket and the SH-3110 stand are available as optional accessories for using the wireless sensors as desktop devices.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255429136715,"sku":"1801-4280-3000-000","price":417.94,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-xx-FSE__solar_mini-mL_4c_048af9fd-bec9-4bf3-923c-ef69f4e9b7ea.png?v=1769675490"},{"product_id":"funkbussystem-kymasgard-rftm-bw-fse-1801-4280-4000-000","title":"KYMASGARD® RFTM-BW-FSE","description":"The room radio sensors of the KYMASGARD® 9000 radio bus system are battery-free and maintenance-free radio transmitters. Energy is generated by converting the light inside the room into electrical energy using a solar generator. If there is insufficient ambient light for energy generation, the sensors can optionally be operated with two AAA batteries (not included). They are used to record the room climate and to set and transmit setpoint values to radio actuators and radio receivers\/gateways via radio. The following device configurations are available: \u003cbr\u003e\u003cbr\u003eThe KYMASGARD® RFTM-FSE room sensor is used to record the room temperature and room humidity. \u003cbr\u003e\u003cbr\u003eThe KYMASGARD® RFTM-FSE-ST room operating unit is used to record the room temperature and room humidity and to display and set the setpoint temperature. The setpoint is set directly on site using touch buttons. \u003cbr\u003e\u003cbr\u003eThe KYMASGARD® RFTM-LQ-FSE room sensor is used to record the room temperature and humidity as well as the air quality (VOC, volatile organic compounds). \u003cbr\u003e\u003cbr\u003eThe KYMASGARD® RFTM-BW-FSE room sensor is used to detect the room temperature and humidity as well as the movement of people (presence). \u003cbr\u003e\u003cbr\u003eThe WH-3100 wall bracket and the SH-3110 stand are available as optional accessories for using the wireless sensors as desktop devices.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":51255429464395,"sku":"1801-4280-4000-000","price":403.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFTM-BW-FSE__solar_maxi-mL_4c.png?v=1769675448"},{"product_id":"kanal-luftqualitaetsfuehler-regler-voc-aerasgard-klq-aw-1501-3150-e301-600","title":"AERASGARD® KLQ-AW","description":"\u003cp\u003ePatented quality product, patent no. DE 10 2014 010 719.1 (FLOW), DE 10 2015 015 941 B4 (AOS) Maintenance-free duct sensor AERASGARD® KLQ-SD with active output, calibratable, in an impact-resistant plastic housing with quick-release screws, incl. mounting flange, for determining the air quality (0...100 % VOC). The transducer converts the measured variables into a standard signal of 0 -10 V.  The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.  The air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc. A low (SLOW), medium (NORMAL) or high (FAST) VOC sensitivity can be set for the expected air contamination.\u003c\/p\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059369488715,"sku":"1501-3150-E301-600","price":244.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KLQ-SD__tyr01-PA6-oF__maxi-mL__4c_74069633-9114-49ae-9894-42eae704f029.png?v=1774612170"},{"product_id":"kanal-luftqualitaetsfuehler-regler-voc-aerasgard-klq-aw-120mm-1501-3150-e301-601","title":"AERASGARD® KLQ-AW 120mm","description":"\u003cp\u003ePatented quality product, patent no. DE 10 2014 010 719.1 (FLOW), DE 10 2015 015 941 B4 (AOS) Maintenance-free duct sensor AERASGARD® KLQ-AW with active\/switching output, calibratable, in an impact-resistant plastic housing with quick-locking screws, incl. mounting flange, for determining the air quality (0...100 % VOC). The measuring transducer automatically detects the required output type (Automatic Output Switching) and converts the measured variables into a standard signal of 0 -10 V or 4...20 mA.  The sensor is used in offices, hotels, conference rooms, apartments, stores etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.  The air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc. A low (SLOW), medium (NORMAL) or high (FAST) VOC sensitivity can be set for the expected air contamination.\u003c\/p\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059369554251,"sku":"1501-3150-E301-601","price":271.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KLQ-SD__tyr01-PA6-oF__maxi-mL__4c.png?v=1774612170"},{"product_id":"klq-sd-u","title":"AERASGARD® KLQ-SD-U","description":"\u003cp\u003ePatented quality product, patent no. DE 10 2014 010 719.1 (FLOW), DE 10 2015 015 941 B4 (AOS) Maintenance-free duct sensor AERASGARD® KLQ-SD with active output, calibratable, in an impact-resistant plastic housing with quick-release screws, incl. mounting flange, for determining the air quality (0...100 % VOC). The transducer converts the measured variables into a standard signal of 0 -10 V.  The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the indoor climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.  The air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc. A low (SLOW), medium (NORMAL) or high (FAST) VOC sensitivity can be set for the expected air contamination.\u003c\/p\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059369718091,"sku":"1501-3170-1001-600","price":234.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KLQ-SD__tyr01-PA6-oF__maxi-mL__4c_2772136e-d588-482c-98f5-5c0cdcc0a202.png?v=1774612182"},{"product_id":"klq-sd-u-120mm","title":"AERASGARD® KLQ-SD-U 120mm","description":"\u003cp\u003ePatented quality product, patent no. DE 10 2014 010 719.1 (FLOW), DE 10 2015 015 941 B4 (AOS) Maintenance-free duct sensor AERASGARD® KLQ-AW with active\/switching output, calibratable, in an impact-resistant plastic housing with quick-locking screws, incl. mounting flange, for determining the air quality (0...100 % VOC).  The measuring transducer automatically detects the required output type (Automatic Output Switching) and converts the measured variables into a standard signal of 0 -10 V or 4...20 mA.  The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.  The air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions, etc. A low (SLOW), medium (NORMAL) or high (FAST) VOC sensitivity can be set for the expected air contamination.\u003c\/p\u003e","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059369750859,"sku":"1501-3170-1001-601","price":274.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/KLQ-SD__tyr01-PA6-oF__maxi-mL__4c_aaab3742-1617-4880-b146-39f3b10bd4b7.png?v=1774612182"},{"product_id":"alq-co2-aw","title":"ALQ-CO2-AW","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059370013003,"sku":"1501-7111-E301-600","price":516.86,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_dd0febfe-f67a-43fb-adde-08d75fd52bbb.jpg?v=1776486797"},{"product_id":"alq-co2-aw-lcd","title":"ALQ-CO2-AW LCD","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059370045771,"sku":"1501-7111-E371-600","price":583.53,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_b49dfbbc-41ad-412f-b4bf-3fb084aee90a.jpg?v=1776486797"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-und-co2-gehalt-aerasgard-aftm-lq-co2-aw-0-10v-4-20ma-1-wechsler-24-v-1501-7118-e301-600","title":"AERASGARD® AFTM-LQ-CO2-AW","description":"Maintenance-free surface-mounted room climate sensor AERASGARD® AFTM - CO2 - W\/ ASGARD® AFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059370275147,"sku":"1501-7118-E301-600","price":650.06,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_64ba3686-93d2-4fdb-ba3d-02aa6af3db89.jpg?v=1776487021"},{"product_id":"aufputzfuehler-fuer-feuchte-temperatur-und-co2-gehalt-aerasgard-aftm-lq-co2-aw-lcd-0-10v-4-20ma-1-wechsler-24-v-1501-7118-e371-600","title":"AERASGARD® AFTM-LQ-CO2-AW LCD","description":"Maintenance-free surface-mounted room climate sensor AERASGARD® AFTM - CO2 - W\/ ASGARD® AFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e A long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059370307915,"sku":"1501-7118-E371-600","price":778.14,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_d4d7d8e9-8190-451c-a85e-ac416cd1125f.jpg?v=1776487021"},{"product_id":"kanal-luftqualitaets-voc-und-co2-fuehler-aerasgard-klq-co2-aw-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-8111-e301-600","title":"AERASGARD® KLQ-CO2-AW","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KLQ-SD with active output, automatic calibration (fixed setting), in a compact plastic housing with snap-on lid, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KLQ-W with active\/switching output, automatic calibration (can be switched off), in a compact plastic housing with quick-locking screws, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e The air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059370438987,"sku":"1501-8111-E301-600","price":430.69,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_0ad4719a-054a-48a6-9793-8fa9134c5ebf.jpg?v=1776487914"},{"product_id":"kanal-luftqualitaets-voc-und-co2-fuehler-aerasgard-klq-co2-aw-lcd-0-10v-4-20ma-1-wechsler-24-v-wechsler-1501-8111-e371-600","title":"AERASGARD® KLQ-CO2-AW LCD","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KLQ-SD with active output, automatic calibration (fixed setting), in a compact plastic housing with snap-on lid, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KLQ-W with active\/switching output, automatic calibration (can be switched off), in a compact plastic housing with quick-locking screws, for determining the air quality or air quality in three VOC sensitivity levels (low\/medium\/high). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable).\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e\u003cbr\u003e The sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being.\u003cbr\u003e\u003cbr\u003e The air quality is measured using a VOC sensor (mixed gas sensor for volatile organic substances). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination.","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059370471755,"sku":"1501-8111-E371-600","price":495.78,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_41a099e5-b28e-4811-a1ff-1a9ef6eb8b3c.jpg?v=1776487916"},{"product_id":"kanalfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-kftm-lq-co2-aw-0-10v-4-20ma-1-wechsler-24-v-1501-8118-e301-600","title":"AERASGARD® KFTM-LQ-CO2-AW","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KTM - CO2 - SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-release screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The measuring transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. .","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059370733899,"sku":"1501-8118-E301-600","price":516.19,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_470fc6e6-ff7d-4cad-8bfa-988f0516e5ba.jpg?v=1776488051"},{"product_id":"kanalfuehler-fuer-feuchte-temperatur-luftguete-und-co2-aerasgard-kftm-lq-co2-aw-lcd-0-10v-4-20ma-1-wechsler-24-v-1501-8118-e371-600","title":"AERASGARD® KFTM-LQ-CO2-AW LCD","description":"Patented quality product (patent no. DE 10 2014 010 719.1) \u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KTM - CO2 - SD with active output, automatic calibration (fixed setting), in an impact-resistant plastic housing with quick-release screws, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm) and the temperature (-35...+80 °C). The measuring transducer converts the measured variables into a standard signal of 0-10 V. \u003cbr\u003e\u003cbr\u003e\u003cbr\u003eMaintenance-free duct sensor AERASGARD® KFTM - LQ - CO2 - W with active\/switching output, automatic calibration (can be switched off), in an impact-resistant plastic housing with quick-release screws, optionally with\/without display, for determining the CO2 content of the air (0...2000 ppm \/ 0...5000 ppm), the air quality or air quality in three VOC sensitivity levels (low\/medium\/high), the temperature (-35...+80 °C) and the relative humidity (0...100 % r.H.). The transducer converts the measured variables into a standard signal of 0-10 V or 4...20 mA (switchable). \u003cbr\u003e\u003cbr\u003eThe sensor is used in offices, hotels, conference rooms, apartments, stores, etc. and is used to evaluate the room climate. This enables energy-saving, needs-based room ventilation and thus a reduction in operating costs and an increase in well-being. \u003cbr\u003e\u003cbr\u003eA long-term stable, digital humidity and temperature sensor guarantees exact measurement results. \u003cbr\u003e\u003cbr\u003eCO2 is measured using an optical NDIR sensor (non-dispersive infrared technology). The detection range is calibrated for standard applications such as residential and conference room monitoring. \u003cbr\u003e\u003cbr\u003eAir quality is measured using a VOC sensor (mixed gas sensor for volatile organic compounds). This determines the pollution of the room air by contaminated gases such as cigarette smoke, body vapors, breathing air, solvent vapors, emissions from parts of the building, etc. A low, medium or high VOC sensitivity can be set for the expected air contamination. .","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56059370799435,"sku":"1501-8118-E371-600","price":581.29,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_4e946b64-36a2-4f49-9f9c-6021b46b2343.jpg?v=1776488052"},{"product_id":"rftm-lq-co2-w","title":"RFTM-LQ-CO2-W","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":56992730710347,"sku":"1501-61B8-7301-600","price":454.23,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/RFF-RFTF__baldur2_maxi-mL_4c_dcef1440-192a-492d-a551-ca9a5619cd5b.png?v=1778044784"},{"product_id":"rftm-lq-co2-w-lcd","title":"RFTM-LQ-CO2-W LCD","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57026898395467,"sku":"1501-61B8-7321-600","price":509.21,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_d60ffe4b-a83b-4a36-8d02-64fbd4167d65.jpg?v=1776489680"},{"product_id":"klq-w","title":"KLQ-W","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57027139961163,"sku":"1501-3150-7301-600","price":244.75,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_0a307458-cac4-45e5-9df1-803f3e02769c.jpg?v=1776488124"},{"product_id":"rlq-sd-u","title":"RLQ-SD-U","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57029590810955,"sku":"1501-61C0-1001-600","price":190.16,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_c64c64a7-8181-4f44-803f-d4277d3dc3a5.jpg?v=1776489698"},{"product_id":"rlq-w","title":"RLQ-W","description":"","brand":"S+S Regeltechnik","offers":[{"title":"Default Title","offer_id":57029592482123,"sku":"1501-61C0-7301-600","price":199.31,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0861\/8626\/2859\/files\/Picture-not-available_23fa24a0-ec8b-4980-a57a-81a99079cd44.jpg?v=1776489700"}],"url":"https:\/\/www.spluss.fr\/en\/collections\/mixed-gases-voc.oembed","provider":"S+S Regeltechnik","version":"1.0","type":"link"}